Odin Bilişim & Teknoloji
Ruijie RG-S2910-24GT4XS-E 24 Port 10/100/1000 4 X 10G SFP Yonetilebilir Rack Mount Switch
Stokta
SwitchlerSKU: 13909Üretici kodu: RG-S2910-24GT4XS-EBarkod: 6971693273962

Ruijie RG-S2910-24GT4XS-E 24 Port 10/100/1000 4 X 10G SFP Yonetilebilir Rack Mount Switch

RUIJIE RG-S2910-24GT4XS-E RG-S2910XS-E Series New-Generation Efficient and Energy-Saving Switches Power consumption reduced by 40% compared with similar products Multi-process modular OS RGOS 11.X developed by Ruijie Networks SDN features...

₺14.380,46
KDV Dahil • Ücretsiz Kargo
Havale/EFT ile %5 indirimli₺13.661,44
12 aya varan taksit • 12 x 1.582,34 TLTaksit seçenekleri
TaksitAylıkToplam
Tek çekim14.380,46 TL14.380,46 TL
2 taksit7.570,66 TL15.141,32 TL
3 taksit5.146,94 TL15.440,82 TL
6 taksit2.745,44 TL16.472,63 TL
9 taksit1.961,36 TL17.652,20 TL
12 taksit1.582,34 TL18.988,03 TL

Geçerli kartlar: World, BankkartCombo, Maximum, Axess, Paraf, QNB CC.

Taksitli ödemelerde banka vade farkı uygulanır; kesin tutar ödeme ekranında kartınıza göre gösterilir.

1
WhatsApp Hızlı Bilgi
  • 2 Yıl GarantiOrijinal Ürün
  • Yerinde MontajTrakya Geneli
  • Hızlı TeslimatGüvenli Kargo
  • Teknik DestekUzman Kadro

Ruijie RG-S2910-24GT4XS-E 24 Port 10/100/1000 4 X 10G SFP Yonetilebilir Rack Mount Switch Hakkında

RUIJIE RG-S2910-24GT4XS-E RG-S2910XS-E Series New-Generation Efficient and Energy-Saving Switches Power consumption reduced by 40% compared with similar products Multi-process modular OS RGOS 11.X developed by Ruijie Networks SDN features and compliance with OpenFlow 1.3 Switch zero-configuration via TR069 Diverse ports Advanced Technologies Learn more about RG-S2910XS-E series technologies > Secure and Reliable Hardware and Software Strict component selection 3-month reliability testing (concerning high and low temperature tolerance, vibration, electromagnetic interference, power surge, signal tests, etc.) Hardware and software-level CPU Protection Policy (CPP) Accurate traffic statistics Unified management and control of 9 virtualized devices Learn more about RG-S2910XS-Esecurity and reliability > Multiple Modes Ensuring Easy Management Creating New Green and Energy-saving Devices Compared with the RG-S5750-S products with the same configuration, the S2910XS-E reduces power consumption by more than 40% . Compared with the RG-S2900G-E products with lower configuration, the S2910XS-E reduces power consumption by about 10% . Up-to-date Processing Chip Ensuring High Performance High-level integration between the MAC chip and CPU, featuring high stability, high reliability, and low-power consumption 512 MB memory and 256 MB flash memory, preventing internal processing bottlenecks Flexible Port Types and On-Demand Expansion A single device supports a maximum of 24/48 gigabit electrical ports and four 10GE SFP ports, and can support line-rate forwarding. PoE switches are configured with two multiplexing downlink SFP ports and two fixed 10GE SFP ports, and can be expanded with two 10GE ports to meet flexible expansion requirements. High-end PoE switches are equipped with USB ports for device upgrades, log backup, and security identification. Multi-Process and Modular OS RGOS 11.X Components (processes) are independent. A breakdown of one component (process) will not affect other components. Compared with non-modular OSs, the possibility of a host reset is reduced by 98%. For example, if the STP component (process) breaks down, the whole device does not reset. Component (process) faults can be automatically rectified. For example, if the STP component (process) breaks down, only the component (process) instead of the whole device will be automatically restarted and be restored to the normal state for running. Strict Component Selection for Optimal Quality Derating design for all components, ensuring universal quality standards for all products Power: High-quality power supplies for use in altitudes ranging from –500 m to 5000 m Fan: Fans with smart speed adjustment to prolong the fan lifespan Dampproof, dustproof, anti-corrosion, anti-fog, anti-salt fog performance with conformal coating to fit different environment Stable Device Running, Always the Foremost of Our Concerns The hardware and software-level CPU Protection Policy (CPP) and Network Foundation Protection Policy (NFPP) are combined. The CPP developed by Ruijie Networks can summarize the quantity of traffic destined for the CPU by category and assign them different priorities to ensure stable CPU running. Combined with the NFPP, the CPP can effectively prevent various attacks to offer the highest-level protection to the CPU and ensure the normal running of various services, thereby guaranteeing stable running of all devices on the network. PoE models, On-Demand Service Management and Control The PoE models complying with 802.3af and 802.3at standards offer dual modular power supplies, supporting PoE+ on all the downlink ports. The switch is equipped with a one-click switching button. Press the button to view the status of current communication and power supply. Power supply to STAs is not interrupted during restart of the HPoE power supply host VSU Technology Virtualizes 9 devices into 1 logical Easy management: The VSU is regarded as one switch in the network .Administrators can centrally manage all the devices at the same time. Millisecond failover: The VSU and peripheral devices connected via the aggregation link. Upon failure event of any device or link, failover to another member link requires only 50 to 200ms. Exceptional scalability: The network is hot swappable, any devices leaving or joining the virtualized network cause zero impact on other devices. Model RG-S2910-24GT4XS-E Ports 24 10/100/1000BASE-T ports 4 1G/10GBASE-X SFP+ ports (non-combo) Expansion Slots N/A Modular Power Slots N/A Fan Slots Fixed Expansion Modules N/A Management Ports 1 console port Switching Capacity 264Gbps Packet Forwarding Rate 96Mpps Max. Number of 10GE Ports 4 PoE N/A Port Buffer 1.5MB RAM 512MB ARP Table 1,000 MAC Address 16K Routing Table Size (IPv4/IPv6) 500 (IPv4/IPv6) ACL Entries In: 1,500 Out: 500 VLAN 4K 802.1q VLANs, Port-based VLAN, MAC-based VLAN, Protocol-based VLAN, Private VLAN, Voice VLAN, QinQ, IP subnet-based VLAN, GVRP, Guest VLAN QinQ Basic QinQ, Flexible QinQ, 1:1 VLAN switching, N:1 VLAN switching, 1:N VLAN switching Link Aggregation AP, LACP (maximum 8 ports can be aggregated), Cross devices AP, Flow balance Port Mirroring Many-to-one mirroring, One-to-many mirroring, Flow-based mirroring, Over devices mirroring, VLAN-based mirroring, VLAN-filtering mirroring, AP-port mirroring, RSPAN, ERSPAN # RG-S2910-10GT2SFP-P-E supports N:1/1:N port mirroring, Flow-based mirroring Spanning Tree Protocols IEEE802.1d STP, IEEE802.1w RSTP, Standard 802.1s MSTP, Port fast, BPDU filter, BPDU guard, TC guard, TC protection, ROOT guard,Spanning Tree Root Guard(STRG) DHCP DHCP server, DHCP client, DHCP snooping, DHCP relay, IPv6 DHCP snooping, IPv6 DHCP client, IPv6 DHCP relay,DHCP Snooping Option 82 Multiple Spanning Tree Protocol (MSTP) Instances 64 Maximum Aggregation Port (AP) 128 SDN OpenFlow 1.0 & 1.3 VSU (Virtual Switch Unit) Support (up to 9 stack members,to ensure the effectiveness of the use, 4 members are recommended* ), Local and distant stacking, Cross-chassis link aggregation in the stack, Stacking via 10G Ethernet ports # All models support the features above except RG-S2910-10GT2SFP-P-E Zero Configuration CWMP(TR069) L2 Features MAC, EEE, ARP, VLAN, Basic QinQ, Felix QinQ, Link aggregation, Mirroring, STP, RSTP, MSTP, Broadcast/Multicast/Unknown unicast storm control, IGMP v1/v2/v3 snooping, IPv6 MLD Snooping v1/v2,IGMP SGVL/IVGL, IGMP querier, IGMP filter, IGMP fast leave, DHCP, Jumbo frame, RLDP, LLDP, REUP, G.8032 ERPS, Layer 2 protocol tunnel Layer 2 Protocols IEEE802.3, IEEE802.3u, IEEE802.3z, IEEE802.3x, IEEE802.3ad, IEEE802.1p, IEEE802.1x, IEEE802.3ab, IEEE802.1Q (GVRP), IEEE802.1d, IEEE802.1w, IEEE802.1s IPv4 Features Ping, Traceroute IPv6 Features ICMPv6, IPv6 Ping, IPv6 Tracert, Manually configure local address, Automatically create local address IPv4 Routing Protocols Static Routing, RIP, OSPF v1/v2 Basic IPv6 Protocols IPv6 addressing, Neighbor Discovery (ND), ICMPv6, IPv6 Ping and IPv6 Tracert IPv6 Routing Protocols Static routing, RIPng, OSPF v3 G.8032 Support ACL Standard/Extended/Expert ACL, Extended MAC ACL, ACL 80, IPv6 ACL, ACL logging, ACL counter, ACL remark, Global ACL, ACL redirect, Time-based ACL, Router ACL, VLAN ACL, Port-Based ACL QoS 802.1p/DSCP/TOS traffic classification; Multiple queue scheduling mechanisms, such as SP, WRR, DRR, SP+WFQ, SP+WRR, SP+DRR; Input / output port-based speed limit; Port-based traffic recognition; Each port supports 8 queue priorities; flow-based rate limiting with the minimum granularity of 8Kbps,Dynamic QoS Reliability VSU (virtualization technology for virtualizing multiple devices into 1); RIP GR; ERPS (G.8032); REUP dual-link fast switching technology; RLDP (Rapid Link Detection Protocol) EEE Format Support IEEE 802.3az standard Security Binding of the IP address, MAC address, and port address; Binding of the IPv6, MAC address, and port address; Filter illegal MAC addresses; Port-based and MAC-based 802.1x; MAB; Portal and Portal 2.0 authentication; ARP-check; DAI; Restriction on the rate of ARP packets; Gateway anti-ARP spoofing; Broadcast suppression; Hierarchical management by administrators and password protection; RADIUS and TACACS+;Change of Authorization; AAA security authentication (IPv4/IPv6) in device login management; SSH and SSH V2.0; BPDU guard; IP source guard; CPP, NFPP; Port protection, CoA(RADIUS change of authorization),SCP (Secure Copy)Dynamic ARP Inspection(DAI) Manageability SNMPv1/v2c/v3, CLI (Telnet / Console), RMON (1, 2, 3, 9), SSH, Syslog / Debug, NTP / SNTP, FTP, TFTP, Web, SFLOW,HTTP or HTTPS # RG-S2910-10GT2SFP-P-E supports SNMPv2c, CLI (Telnet / Console), Syslog, RMON (1, 2, 3, 9), Web Hot Patch Support Smart Temperature Control Auto fan speed adjustment; Fan malfunction alerts; Fan status check # All models support the features above except RG-S2910-10GT2SFP-P-E Smart Power Supply N/A Other Protocols FTP, TFTP, DNS client, DNS static Dimensions (W x D x H) (mm) 440 × 260 × 43.6 Rack Height 1RU Weight ≤3.5kg MTBF (hours) >200K Lightning Protection on Power Port Common Mode 6KV/Differential Mode 6KV Lightening Protection on Communication Port Common Mode 6KV Power Supply AC input: Rated voltage range: 100V to 240V AC Maximum voltage range: 90V to 264V AC Frequency: 50/60Hz Rated current: 1.5A HVDC input: Input voltage range: 192V to 290V DC Input current range: 0.5A to 0.1A Power Consumption 24W PoE Power N/A Safety Standards IEC 60950-1, EN 60950-1 Emission Standards EN 300 386, EN 55022/55032, EN 61000-3-2, EN 61000-3-3, EN 55024, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-4-11 Temperature Operating temperature: 0°C to 50°C Storage temperature: -40°C to 70°C Humidity Operating humidity: 10% to 90%RH Storage humidity: 5% to 95%RH Operating Altitude -500m to 5,000m

Öne Çıkan Donanım Özellikleri

✓Port Sayısı: 24 Port
✓Veri Transfer Hızı: 10/100/1000
✓POE Desteği: Yok
✓SFP Port: Var
✓Yönetim: Yönetilebilir
✓Rackmount: Var
Odin Bilişim Saha & Entegrasyon Desteği:Tüm donanım ve çevre birimleri, Trakya genelinde (Çorlu, Çerkezköy, Kapaklı, Süleymanpaşa, Ergene, Muratlı) uzman ekibimiz tarafından sahada yerinde kurulup test edilerek teslim edilir.
MÜŞTERİ DEĞERLENDİRMELERİ

Ürün Değerlendirmeleri

Bu ürün için henüz değerlendirme yok. Ürünü sitemizden satın aldıysanız ilk değerlendirmeyi siz yazabilirsiniz.

Henüz yayınlanmış değerlendirme bulunmuyor.

Fiyat₺14.380,46
1